Precaution [07/2020 - ]
- INITIALIZATION NOTE:
When disconnecting the cable from the negative (-) auxiliary battery terminal, initialize the following system(s) after the cable is reconnected.
System Name See Procedure Lane Tracing Assist System Refer to INITIALIZATION [07/2020 - ] Intelligent Clearance Sonar System Simple Advanced Parking Guidance System Power Door Lock Contrl System Pre-collision System AFS (Adaptive Front-lighting System) - CHARGING SYSTEM PRECAUTION WARNING:
- Orange wire harnesses and connectors indicate high-voltage circuits. To prevent electric shock, always follow the procedure described in the repair information.
Refer to PRECAUTION [08/2019 - ]
- To prevent electric shock, wear insulated gloves when working on wire harnesses and components of the high voltage system.
NOTE:- If the auxiliary battery is fully depleted or the READY indicator does not illuminate, recharge the auxiliary battery.
- Never disconnect the auxiliary battery while the power switch is on (READY).
- Before giving the auxiliary battery a quick charge, disconnect the auxiliary battery cables.
- Check the auxiliary battery again before the vehicle is returned to the customer.
- When replacing the auxiliary battery with a new one, use an auxiliary battery with the same physical dimensions (LN 1), a cold cranking ampere (CCA) 295 A or more, and a 20-hour rate capacity of 45 Ah or more.
- Orange wire harnesses and connectors indicate high-voltage circuits. To prevent electric shock, always follow the procedure described in the repair information.