Unit inspection
- Ignition/starter switch ASSY check
- Measure the resistance between connector terminals.
RESISTANCE SPECIFICATION
| Inspection terminals | Inspection conditions | Standard value |
|---|---|---|
| - | LOCK | 10 k Ωor more |
| 2 (AM1) - 3 (ACC) | ACC | Less than 1 Ω |
| 2 (AM1) - 3 (ACC) - 4 (IG1) | ON | Less than 1 Ω |
| 6 (IG2) - 7 (AM2) | ||
| 1 (ST1) - 2 (AM1) - 4 (IG1) | START | Less than 1 Ω |
| 6 (IG2) - 7 (AM2) - 8 (ST2) |