Reference Value - King Cab®
TERMINAL LAYOUT
PHYSICAL VALUES
| Terminal No. (Wire color) | Description | Condition | Value (Approx.) | ||
|---|---|---|---|---|---|
| + | - | Signal name | Input/Output | ||
| 1 (LG) | Ground | Ignition switch power supply | Input | Ignition switch ON | Battery voltage |
| Other than above | 0 V | ||||
| 2 (B) | Ground | Front power window motor RH DOWN signal | Output | When power window motor is operated DOWN | Battery voltage |
| 3 (BG) | Ground | Encoder pulse signal 1 | Input | When power window motor operates | |
| 4 (R) | Ground | Encoder pulse signal 2 | Input | When power window motor operates | |
| 5 (G) | Ground | Unlock switch signal | Output | Key position (Neutral → Unlocked) | 5 → 0 V |
| 6 (L) | Ground | Lock switch signal | Output | Key position (Neutral → Locked) | 5 → 0 V |
| 7 (W) | Ground | Front power window motor LH UP signal | Output | When power window motor is operated UP | Battery voltage |
| 9 (L) | Ground | Front power window motor RH UP signal | Output | When power window motor is operated UP | Battery voltage |
| 11 (P) | Ground | Encoder power supply | Output | When ignition is ON or power window timer operates. | Battery voltage |
| 12 (B) | Ground | Encoder ground | - | - | 0 V |
| 13 (B) | Ground | Ground | Output | - | 0 V |
| 15 (V) | Ground | Battery power supply | Input | - | Battery voltage |
| 16 (R) | Ground | Front power window motor LH DOWN signal | Output | When power window motor is operated DOWN | Battery voltage |