Diagnosis Procedure
Regarding Wiring Diagram information, refer to the appropriate Wiring Diagram (With Left and Right Front Auto Up/Down).
- CHECK POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH RH OUTPUT SIGNAL
- Remove Intelligent Key, and close the front door LH and RH.
- Check signal between BCM connector and ground with oscilloscope when door lock and unlock switch (LH and RH) is turned to "LOCK" or "UNLOCK".
- Check that signals which are shown in the figure below can be detected during 10 second just after door lock and unlock switch (LH and RH) is turned to "LOCK" or "UNLOCK".
Terminal
Signal
(Reference value)
(+)
(-)
BCM connector
Terminal
M19
54
Ground
Is the inspection result normal?
YES
Power window serial link is OK.
NO
GO TO 2
- CHECK POWER WINDOW SERIAL LINK CIRCUIT
- Turn ignition switch OFF.
- Disconnect BCM.
- Check continuity between BCM connector M19 and power window and door lock/unlock switch RH connector D129.
BCM connector
Terminal
Power window and door lock/unlock switch RH connector
Terminal
Continuity
M19
54
D129
3
Yes
- Check continuity between BCM connector M19 and ground.
BCM connector
Terminal
Ground
Continuity
M19
54
No
Is the inspection result normal?
YES
Replace power window and door lock/unlock switch RH. Refer to Removal and Installation . After that, refer to Work Procedure .
NO
Repair or replace the harness or connectors.