Main Power Window And Door Lock/Unlock Switch Power Supply Circuit Check
- CHECK POWER SUPPLY CIRCUIT
- Turn ignition switch ON.
- Check voltage between main power window and door lock/unlock switch connectors D5, D11 and ground.
Terminal Voltage
(Approx.)(+) (-) Main power window and door lock/unlock switch Terminal D5 10 Ground Battery voltage D11 18
Is the inspection result normal?
YES
GO TO STEP 3 .
NO
GO TO STEP 2.
- CHECK HARNESS CONTINUITY
- Turn ignition switch OFF.
- Disconnect BCM, main power window and door lock/unlock switch, power window and door lock/unlock switch RH, rear power window switch LH and rear power window switch RH.
- Check continuity between BCM connector and main power window and door lock/unlock switch connectors.
With Intelligent Key system
BCM
connectorTerminal Main power window and door lock/unlock switch
connectorTerminal Continuity M85 92 D5 10 Yes 91 D11 18 Without Intelligent Key system
BCM
connectorTerminal Main power window and door lock/unlock switch
connectorTerminal Continuity M20 68 D5 10 Yes 69 D11 18 - Check continuity between BCM connector M85 or M20 and ground.
With Intelligent Key system
BCM connector Terminal Ground Continuity M85 91 No 92 Without Intelligent Key system
BCM connector Terminal Ground Continuity M20 68 No 69
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Repair or replace the harness or connectors.
- CHECK GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect main power window and door lock/unlock switch.
- Check continuity between main power window and door lock/unlock switch connector D5 and ground.
Main power window and door lock/unlock switch connector Terminal Ground Continuity D5 1 Yes
Is the inspection result normal?
YES
Check main power window and door lock/unlock switch output signal (rear power window switch LH) GO TO STEP 5.
YES
Check main power window and door lock/unlock switch output signal (rear power window switch RH) GO TO STEP 6 .
YES
Check main power window and door lock/unlock switch output signal (front power window switch LH) GO TO STEP 7 .
YES
Check main power window and door lock/unlock switch output signal (front power window switch RH) GO TO STEP 8 .
NO
Repair or replace the harness or connectors.
- CHECK BCM OUTPUT SIGNAL
- Connect BCM.
- Turn ignition switch ON.
- Check voltage between BCM connector M85 or M20 and ground.
With Intelligent Key system
Terminals Voltage
(Approx.)(+) (-) BCM connector Terminal M85 91 Ground Battery voltage 92 Without Intelligent Key system
Terminals Voltage
(Approx.)(+) (-) BCM connector Terminal M20 68 Ground Battery voltage 69
Is the inspection result normal?
YES
Check intermittent incident. Refer to INTERMITTENT INCIDENT .
NO
Replace BCM. Refer to REMOVAL AND INSTALLATION (with Intelligent Key) or REMOVAL AND INSTALLATION (without Intelligent Key).
- CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH OUTPUT SIGNAL (REAR POWER WINDOW SWITCH LH)
- Connect main power window and door lock/unlock switch.
- Turn ignition switch ON.
- Check voltage between main power window and door lock/unlock switch D5 and ground.
Terminal Window switch
position (rear LH)Voltage
(Approx.)(+) (-) Main power window and door lock/unlock switch connector Terminal D5 9 Ground UP Battery voltage DOWN 0 8 UP 0 DOWN Battery voltage Is the inspection result normal?
YES
Check intermittent incident. Refer to INTERMITTENT INCIDENT .
NO
Replace main power window and door lock/unlock switch. Refer to REMOVAL AND INSTALLATION . After that, refer to WORK PROCEDURE .
- CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH OUTPUT SIGNAL (REAR POWER WINDOW SWITCH RH)
- Connect main power window and door lock/unlock switch.
- Turn ignition switch ON.
- Check voltage between main power window and door lock/unlock switch D5 and ground.
Terminal Window switch
position (rear RH)Voltage
(Approx.)(+) (-) Main power window and door lock/unlock switch connector Terminal D5 7 Ground UP Battery voltage DOWN 0 6 UP 0 DOWN Battery voltage Is the inspection result normal?
YES
Check intermittent incident. Refer to INTERMITTENT INCIDENT .
NO
Replace main power window and door lock/unlock switch. Refer to REMOVAL AND INSTALLATION . After that, refer to WORK PROCEDURE .
- CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH OUTPUT SIGNAL (FRONT POWER WINDOW SWITCH LH)
- Connect main power window and door lock/unlock switch.
- Turn ignition switch ON.
- Check voltage between main power window and door lock/unlock switch D11 and ground.
Terminal Window switch
position (front LH)Voltage
(Approx.)(+) (-) Main power window and door lock/unlock switch connector Terminal D11 17 Ground UP Battery voltage DOWN 0 19 UP 0 DOWN Battery voltage Is the inspection result normal?
YES
Check intermittent incident. Refer to INTERMITTENT INCIDENT .
NO
Replace main power window and door lock/unlock switch. Refer to REMOVAL AND INSTALLATION . After that, refer to WORK PROCEDURE .
- CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH OUTPUT SIGNAL (FRONT POWER WINDOW SWITCH RH)
- Connect main power window and door lock/unlock switch.
- Turn ignition switch ON.
- Check voltage between main power window and door lock/unlock switch D5 and ground.
Terminal Window switch
position (front RH)Voltage
(Approx.)(+) (-) Main power window and door lock/unlock switch connector Terminal D5 16 Ground UP Battery voltage DOWN 0 2 UP 0 DOWN Battery voltage Is the inspection result normal?
YES
Check intermittent incident. Refer to INTERMITTENT INCIDENT .
NO
Replace main power window and door lock/unlock switch. Refer to REMOVAL AND INSTALLATION . After that, refer to WORK PROCEDURE .