LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2011 >> Sentra SE-R >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control System - DTCS P0447 To P0850 (Qr25DE) >> DTC P0447 EVAP Canister Vent Control Valve >> Diagnosis Procedure

Diagnosis Procedure

  1. INSPECTION START
    1. Do you have CONSULT-III?

    Yes or No 

    Yes: GO TO 2.

    No: GO TO  2.

  2. CHECK EVAP CANISTER VENT CONTROL VALVE CIRCUIT

    With CONSULT-III 

    1. Turn ignition switch OFF and then turn ON.
    2. Select "VENT CONTROL/V" in "ACTIVE TEST" mode with CONSULT-III.
    3. Touch "ON/OFF" on CONSULT-III screen.
    4. Check for operating sound of the valve.

      Clicking noise should be heard  .

    OK or NG 

    OK: GO TO  8.

    NG: GO TO 3.

  3. CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY CIRCUIT
    1. Turn ignition switch OFF.
    2. Disconnect EVAP canister vent control valve (3) harness connector.
      • This illustration is a view from under vehicle
      • EVAP control system pressure sensor (1)
      • EVAP canister (2)
    3. Turn ignition switch ON.
      Fig 1: Location Of EVAP Control System Pressure Sensor, EVAP Canister And EVAP Canister Vent Control Valve
      G07144289Courtesy of NISSAN MOTOR CO., U.S.A.
    4. Check voltage between EVAP canister vent control valve terminal 1 and ground with CONSULT-III or tester.

      Voltage: Battery voltage 

      Fig 2: Checking Voltage Between ECT Sensor Terminal 1 And Ground
      G07144290Courtesy of NISSAN MOTOR CO., U.S.A.

    OK or NG 

    OK: GO TO  5.

    NG: GO TO 4.

  4. DETECT MALFUNCTIONING PART

    Check the following.

    • Harness connectors B9, E13
    • Harness for open or short between EVAP canister vent control valve and IPDM E/R

      Repair open circuit or short to ground or short to power in harness or connectors.

  5. CHECK EVAP CANISTER VENT CONTROL VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check harness continuity between ECM terminal 109 and EVAP canister vent control valve terminal 2.

      Refer to WIRING DIAGRAM .

      Continuity should exist  .

    4. Also check harness for short to ground and short to power.

    OK or NG 

    OK: GO TO 6.

    NG: Repair open circuit or short to ground or short to power in harness or connectors.

  6. CHECK RUBBER TUBE FOR CLOGGING
    1. Disconnect rubber tube connected to EVAP canister vent control valve.
    2. Check the rubber tube for clogging.

    OK or NG 

    OK: GO TO 7.

    NG: Clean the rubber tube using an air blower.

  7. CHECK DRAIN FILTER

    Refer to "COMPONENT INSPECTION ".

    OK or NG 

    OK: GO TO 8.

    NG: Replace drain filter.

  8. CHECK EVAP CANISTER VENT CONTROL VALVE

    Refer to "COMPONENT INSPECTION ".

    OK or NG 

    OK: GO TO 9.

    NG: Replace EVAP canister vent control valve. Refer to "REMOVAL AND INSTALLATION ".

  9. CHECK INTERMITTENT INCIDENT

    Refer to TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT .

    INSPECTION END