Adjustment for Rack Sliding Force: Increase
Increase rack sliding force as follows:
- Tighten adjusting screw until it is flush with housing surface.
- Loosen adjusting screw in 40° - 60° increments until rack sliding force is within specification.
Average rack sliding force : 210.7 - 298.9 N (21.49 - 30.49 kg-f, 47.37 - 67.19 lb-f)
Maximum force deviation : 98 N (10 kg-f, 22 lb-f)
NOTE: Steering gear must replaced if adjusting screw rotation torque is less than 5.0 N.m (0.9 kg-m, 44 in-lb). - Verify rack sliding force. Refer to , "CHECKING RACK SLIDING FORCE ".
- If rack sliding force is out of specification, adjust rack sliding force again.
- If rack sliding force cannot be adjusted within specification, replace steering gear.