ABS Warning Lamp Does Not Come On When Ignition Switch Is Turned On
- CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) FUSIBLE LINKS
Check 40A fusible link f and 40A fusible link l for ABS actuator and electric unit (control unit). For fusible link layout, refer to "POWER SUPPLY ROUTING CIRCUIT ".
OK or NG
OK: GO TO 2.
NG: If fusible link is blown, be sure to eliminate cause of problem before replacing.
- CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) POWER SUPPLY CIRCUITS
- Disconnect ABS actuator and electric unit (control unit) connector.
- Check voltage between ABS actuator and electric unit (control unit) connector terminal 1 and ground and terminal 2 and ground.
Does battery voltage exist?
Yes: GO TO 3.
NO: Repair harness or connectors between fusible link and ABS actuator and electric unit (control unit).
- CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) GROUND CIRCUIT
Check continuity between ABS actuator and electric unit (control unit) connector terminal 3 and ground and terminal 4 and ground.
Does continuity exist?
YES: Replace ABS actuator and electric unit (control unit). Refer to "REMOVAL AND INSTALLATION ".
NO: Repair harness or connectors between ABS actuator and electric unit (control unit) and ground.