If data monitor function of M-MDS is used
- Warm up the engine and idle it.
- Connect the M-MDS to the DLC-2.
- Select the PCM PIDs [ENG_RPM] and [FUEL_PULSE_WD]. (See PID/DATA MONITOR INSPECTION
.)
- Monitor both PIDs while performing the following steps:
- Depress the accelerator pedal and increase the [ENG_RPM] PID to 4, 000 rpm.
- Quickly release the accelerator pedal (brake pedal is not depressed) and verify that the [FUEL_PULSE_WD] PID is 0 msec, and 2 -5 msec when the [ENG_RPM] PID drops below 1, 200 rpm.
- If not as specified, inspect the following: