LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2022 >> CX-5 S Select >> Repair and Diagnosis >> External Pages >> Different car >> Section 277 (Basic System) >> Expansion Valve Removal/Installation >> VIN M

VIN M

WARNING: This page is about a different car, the 2021 Mazda CX-5. However, it is still accessible from the selected car via links, so may be relevant.
  1. Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)
  2. Discharge the refrigerant. (See REFRIGERANT RECOVERY .) (See REFRIGERANT CHARGING .)
  3. Remove the plug hole plate. (See PLUG HOLE PLATE REMOVAL/INSTALLATION [VIN M] .)
  4. Disconnect the refrigerant pressure sensor connector.
    Fig 1: Refrigerant Pressure Sensor Connector, Engine Ground, Cooler Pipe, Cooler Hose, Bolts And Nuts With Torque Specification
    G11430234Courtesy of MAZDA MOTORS CORP.
  5. Remove the bolt.
  6. Disconnect the engine ground.
  7. Remove the nut.
  8. Remove the clip.
  9. Remove the bolt.
    Fig 2: Cooler Pipe, Cooler Hose And Bolts With Torque Specification
    G11430235Courtesy of MAZDA MOTORS CORP.
  10. Disconnect the cooler hose (LO) and cooler pipe. Do not allow compressor oil to spill.
    CAUTION:
    • If moisture or foreign material enters the refrigeration cycle, cooling ability will be lowered and abnormal noise will occur. Always immediately plug all open fittings after removing any refrigeration cycle parts to keep moisture or foreign material out of the cycle.
  11. Set the cooler hose (LO) and cooler pipe aside as shown in the figure while being careful not to let remaining oil in the pipes to spill.
    G11430236Courtesy of MAZDA MOTORS CORP.
    CAUTION:
    • When setting the cooler hose (LO) and cooler pipe aside, only bend the flexible part of the hose. If force is applied to areas other than the flexible hose, the pipe will bend and could be damaged.
  12. Remove the bolts.
    Fig 3: Expansion Valve And Bolts With Torque Specification
    G11430237Courtesy of MAZDA MOTORS CORP.
  13. Remove the expansion valve. Do not allow compressor oil to spill.
    CAUTION:
    • If moisture or foreign material enters the refrigeration cycle, cooling ability will be lowered and abnormal noise will occur. Always immediately plug all open fittings after removing any refrigeration cycle parts to keep moisture or foreign material out of the cycle.
  14. Install in the reverse order of removal.
  15. Perform the refrigerant system performance test. (See REFRIGERANT SYSTEM PERFORMANCE TEST .)