Choke Return System
When cold engine is started with assist of choke knob, the knob is held in pulled position by the choke magnet. Full release of choke knob is achieved as engine coolant temperature reaches 158°F (70°C). The No. 1 water temperature switch stops the flow of electrical current to magnet and the choke knob is released.