Inspection [10/2015 - ]: Procedure
- INSPECT FUEL SENDER GAUGE ASSEMBLY
*a Component without harness connected
(Fuel Sender Gauge Assembly)Check that the float moves smoothly between F and E.
- Measure the resistance according to the value (s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 2 - 3 Float position is F (Upper) 6.5 to 8.5 Ω Float position is E (Lower) 194.4 to 199.4 Ω If the value is not as specified, replace the fuel sender gauge assembly.
- INSPECT NO. 2 FUEL SENDER GAUGE ASSEMBLY
*a Component without harness connected
(No. 2 Fuel Sender Gauge Assembly)Check that the float moves smoothly between F and E.
- Measure the resistance according to the value (s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 Float position is F (Upper) 6.5 to 8.5 Ω Float position is E (Lower) 210.1 to 216.1 Ω If the value is not as specified, replace the No. 2 fuel sender gauge assembly.