Inspection Procedure
- READ DATA LIST (ENGINE COOLANT TEMPERATURE)
- Connect the intelligent tester to the CAN VIM. Then connect the CAN VIM to the DLC3.
- Turn the engine switch on (IG) and turn the tester ON.
- Enter the following menus: DIAGNOSIS / ENHANCED OBD II / DATA LIST / ALL / COOLANT TEMP.
- Read the values.
Standard:
Same value as the actual ECT.
Result
RESULT CHARTEngine Coolant Temperature Proceed to -40°C (-40°F) A 140°C (284°F) or more B OK (same as present temperature) C HINT:
If there is an open circuit, the intelligent tester indicates -40°C (-40°F).
If there is a short circuit, the intelligent tester indicates 140°C (284°F) or more.
B: Go to step 4
C: CHECK FOR INTERMITTENT PROBLEMS
A: Go to next step
- READ DATA LIST (CHECK FOR OPEN IN WIRE HARNESS)
- Disconnect the E40 ECT sensor connector.
- Connect terminals 1 and 2 of the ECT sensor wire harness side connector.
- Turn the engine switch on (IG).
- Read the value.
Standard:
140°C (284°F) or more
OK: CONFIRM GOOD CONNECTION AT SENSOR. IF OK, REPLACE ENGINE COOLANT TEMPERATURE SENSOR
NG: Go to next step
- READ DATA LIST (CHECK FOR OPEN IN ECM)
- Disconnect the E40 ECT sensor connector.
- Connect terminals the E6 and E8 ECM connectors.
HINT:
Before checking, do a visual and contact pressure check for the ECM connector.
- Turn the engine switch on (IG).
- Read the value.
Standard:
140°C (284°F) or more
NG: CONFIRM GOOD CONNECTION AT ECM. IF OK, REPLACE ECM
OK: REPAIR OR REPLACE HARNESS AND CONNECTOR
- READ DATA LIST (CHECK FOR SHORT IN WIRE HARNESS)
- Disconnect the E40 ECT sensor connector.
- Turn the engine switch on (IG).
- Read the value.
Standard:
-40°C (-40°F)
OK: REPLACE ENGINE COOLANT TEMPERATURE SENSOR
NG: Go to next step
- READ DATA LIST (CHECK FOR SHORT IN WIRE HARNESS)
- Disconnect the E40 ECT sensor connector.
- Disconnect the E6 and E8 ECM connectors.
- Turn the engine switch on (IG).
- Read the value.
Standard:
-40°C (-40°F)
NG: REPLACE ECM
OK: REPAIR OR REPLACE HARNESS AND CONNECTOR