LEMON Manuals: Even more car manuals for everyone
Home >> Kia >> 2024 >> Forte LXS >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Hydraulic System >> Driven Pulley Control Solenoid Valve (Secondary_VFS) >> Repair Procedures >> On Vehicle Inspection >> Component Inspection

Component Inspection

  1. Ignition Switch "OFF".
  2. Disconnect the battery negative (-) cable.
  3. Remove the air cleaner.

    (Refer to Engine Mechanical System - "AIR CLEANER ")

  4. Disconnect the IVT main connector (A).
    G14564668Courtesy of KIA MOTORS AMERICA, INC.
  5. Measure the resistance between power terminal (10) and signal terminal (7).

    Specification:  5.3 ± 0.3 Ω

    G14564669Courtesy of KIA MOTORS AMERICA, INC.