Diagnostic Test
- CHECK FOR AN ACTIVE DTC
- Turn the ignition on.
- With the scan tool, read DTCs.
Does the scan tool read: B161A-COURTESY/DOME LAMP CONTROL CIRCUIT?
Yes
- Go To 2.
No
- Test complete, the condition or conditions that originally set this DTC are not present at this time. Using the wiring diagrams as a guide, check all related splices and connectors for signs of water intrusion, corrosion, pushed out or bent terminals, and correct pin tension.
- CHECK THE (M24) COURTESY LAMPS DRIVER CIRCUIT FOR A SHORT TO GROUND
Courtesy of CHRYSLER GROUP, LLC
- Turn the ignition off.
- Disconnect the Cluster C2 harness connector.
- Measure the resistance between the (M24) Courtesy Lamp Driver circuit and ground.
Is the resistance below 5.0 Ohms?
Yes
- Repair the short to ground in the (M24) Courtesy Lamp Driver circuit.
- Perform the BODY VERIFICATION TEST. Refer to STANDARD PROCEDURE - BODY VERIFICATION TEST .
No
- Go To 3.
- CHECK THE (M24) COURTESY LAMPS DRIVER CIRCUIT FOR AN OPEN
- Turn the ignition off.
- Disconnect the Dome Lamp harness connector.
- Measure the resistance of the (M24) Courtesy Lamp Driver circuit between the Cluster C2 and Dome Lamp harness connectors.
Is the resistance above 5.0 Ohms?
Yes
- Repair the open in the (M24) Courtesy Lamp Driver circuit.
- Perform the BODY VERIFICATION TEST. Refer to STANDARD PROCEDURE - BODY VERIFICATION TEST .
No
- Replace the Cluster in accordance with the Service Information.
- Perform the BODY VERIFICATION TEST. Refer to STANDARD PROCEDURE - BODY VERIFICATION TEST .