Inspection Procedure
- CHECK BATTERY TERMINALS CONNECTION
Check if battery terminals are clean and tight.
Is the inspection result normal?
YES: GO TO 2.
No: Repair battery terminals connection.
- CHECK FUSE
Check for blown fuse and fusible link.
BLOWN FUSE AND FUSIBLE LINK CHARTUnit Power source (Power supply terminals) Fuse or Fusible Link Generator Battery (terminal 3) Fuse 30 Battery (terminal 1) Fusible Link A Combination meter Ignition switch ON (terminal 2) Fuse 14 Is the inspection result normal?
YES: GO TO 3.
No: Be sure to eliminate cause of malfunction before installing new fuse or fusible link.
- CHECK GENERATOR GROUND TERMINAL CONNECTION
Verify connector E206 terminal 5 (generator ground harness) is clean and tight.
Is the inspection result normal?
YES: GO TO 4.
No: Repair connection.
- CHECK DRIVE BELT TENSION
Check drive belt tension. Refer to "CHECKING DRIVE BELTS ".
Is the inspection result normal?
YES: Inspection End.
No: Repair as needed.