Solenoid Operation Chart - Converter Engaged
SOLENOID OPERATION CHART - CONVERTER ENGAGED
| Selector Lever Position | PCM Commanded Gear | Solenoid States - Converter Engaged | |||||
|---|---|---|---|---|---|---|---|
| Shift Solenoid A (SSA) (ON/OFF) | Shift Solenoid B (SSB) (ON/OFF) | Shift Solenoid C (SSC) (PWM) | Shift Solenoid D (SSD) (PWM) | Shift Solenoid E (SSE) (PWM) | PCA | ||
| D | 2 | Off | On | On | Off | On | - |
| - | 3 | Off | On | On | Off | Off | - |
| - | 4 | On | On | On | Off | Off | - |