Starter Ground Connection Resistance Test
Connect voltmeter negative lead to negative battery post. Connect voltmeter positive lead to starter housing. Crank engine and observe voltmeter reading. If voltmeter reading indicates more than 0.2 volt, repair poor starter-to-ground connection.