LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2021 >> Traverse LS, 4WD >> Repair and Diagnosis >> Quick Lookups >> Technical Bulletins >> Technical Service Bulletins >> Other Variant >> HVAC Control Systems >> Ac Blows Warm Or Poor Performance (PIT5099H)

Ac Blows Warm Or Poor Performance (PIT5099H)

WARNING: This page is about the Traverse High Country, 4WD, which is a different variant/trim than selected.
Publication date: 2024-08-20
Reference number: PIT5099H
Supersedes refnos: PIT5099, PIT5099A, PIT5099B, PIT5099C, PIT5099D, PIT5099E, PIT5099F, PIT5099G

AC BLOWS WARM OR POOR PERFORMANCE

AC BLOWS WARM OR POOR PERFORMANCE

TECHNICAL SERVICE BULLETIN

Reference Number(s): PIT5099H, Date of Issue:  Aug 20, 2024

SERVICE INFORMATION

Brand: Model: Model Year: VIN: Engine: Transmission:
from to from to
All All 2000-2024 All All All All

Supersession Statement

This PI was superseded to update recommendation. Please discard PIT5099G.

The following diagnosis might be helpful if the vehicle exhibits the symptom(s) described in this PI.

CONDITION / CONCERN

Customer may comment that their A/C blows warm or they have poor A/C performance.

RECOMMENDATIONS / INSTRUCTIONS

When technical assistance is required and before calling GM TAC, the following information will be helpful in assisting with diagnosing the vehicle.

Please have the following information available:

* A/C High and Low pressures from actual A/C gauges.

High side sensor reading from GDS

A/C compressor duty cycle

Refrigerant solenoid valve command in HVAC data (if equipped)

Outside temperature

Humidity

Vent temperature

If the unit is equipped with an Automatic HVAC system, go into the HVAC data with the scan tool and get the following readings:

* Evaporator temperature sensor reading (if equipped)

* Inside temperature sensor reading

* Outside temperature sensor reading

* Duct temperature sensor readings

NOTE:

Dealers should always be prepared to provide SI Doc ID(s) or Bulletin / PI #(s) when calling into GM TAC.

SERVICE INFORMATION

Please follow this diagnostic or repair process thoroughly and complete each step. If the condition exhibited is resolved without completing every step, the remaining steps do not need to be performed.