Component Testing
M30 Liftgate Latch-Dynamic Test
- Ignition/Vehicle - Off
- Disconnect the electrical connector: M30 Liftgate Latch
- Connect a jumper wire between the test points: Ground terminal 1 & Ground
- Momentarily connect a 7.5 A fused jumper wire between the test points: Control terminal 2 & 12 V
Verify the component turns On and Off when connecting and disconnecting the jumper wire: M30 Liftgate Latch
- If the component does not turn On and Off
Replace the component: M30 Liftgate Latch
- Go to next step: If the component turns On and Off
- If the component does not turn On and Off
- All OK.
S46B Liftgate Unlatch Switch
- Ignition/Vehicle - Off
- Disconnect the electrical connector: S46B Liftgate Unlatch Switch
- Test for infinite resistance between the test points: Signal terminal 2 & Ground terminal 1 - The switch is in the open position.
- If less than infinite resistance
Replace the component: S46B Liftgate Unlatch Switch
- Go to next step: If infinite resistance
- If less than infinite resistance
- Test for less than 3 Ω between the test points: Signal terminal 2 & Ground terminal 1 - The switch is in the closed position.
- If 3 Ω or greater
Replace the component: S46B Liftgate Unlatch Switch
- Go to next step: If less than 3 Ω
- If 3 Ω or greater
Relay Test
- Ignition/Vehicle - Off
- Remove the component: KR95A Liftgate Unlatch Relay
- Test for 70 to 110 Ω between the test points: Component terminal 85 & 86
- If not between 70 and 110 Ω
Replace the component: KR95A Liftgate Unlatch Relay
- Go to next step: If between 70 and 110 Ω
- If not between 70 and 110 Ω
- Test for infinite resistance between the test points:
- Component terminal 30 & 85
- Component terminal 30 & 86
- Component terminal 30 & 87
- Component terminal 85 & 87
- If less than infinite resistance
Replace the component: KR95A Liftgate Unlatch Relay
- Go to next step: If infinite resistance
- Connect a 3 A fused jumper wire between the test points: Component terminal 86 & 12 V
Connect a jumper wire between the test points: Component terminal 85 & Ground
- Test for less than 2 Ω between the test points: Component terminal 30 & 87
- If 2 Ω or greater
Replace the component: KR95A Liftgate Unlatch Relay
- Go to next step: If less than 2 Ω
- If 2 Ω or greater
- All OK.