LEMON Manuals: Even more car manuals for everyone
Home >> Alfa Romeo >> 2021 >> Stelvio Quadrifoglio >> Repair and Diagnosis >> Body & Frame >> Door Locks >> (Power Liftgate Module (PLGM) - Electrical Diagnostics) >> DTC Troubleshooting >> B24E-46 Power Liftgate Module Internal-Calibration/Parameter Memory Failure >> Diagnostic Test

Diagnostic Test

  1. READ AND RECORD (PLGM) DTCS AND ENVIRONMENTAL DATA - ERASE DTCS AND CHECK FOR THE DTC TO RETURN 
    1. With the scan tool, read (PLGM) DTCs and record on the repair order.
    2. For future reference, with the scan tool, run and save a vehicle Scan Report and all related recorded data.
    3. With the scan tool, erase all DTCs.
    4. Turn the ignition off for a minimum of 10.0 seconds.
    5. Turn the ignition on.
    6. Using the When Monitored and Set Conditions above and recorded data, operate the vehicle in the conditions that set the DTC.
    7. With the scan tool, read DTCs.

      Did the DTC return?

      Yes 

      • Go To  2

      No 

  2. PERFORM CALIBRATION UPDATE 
    1. Connect Diagnostic Tool. Go to "Different Functions" and perform the "Learning Process Parameters."

      Did the DTC return?

      Yes 

      No 

      • Performing the special procedure repaired the fault.
      • Test complete. Perform the BODY VERIFICATION TEST. Refer to BODY VERIFICATION TEST .