VCENT Shorted Wire Inspection
NOTICE:
Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.
Test Procedure
- Preparation
-
- -
PCM connector E (80P): disconnected
- -
A/F sensor (Sensor 1) connector (6P): disconnected
- -
- Procedure
-
- -
Perform the inspection according to the following table.
Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
- -
(Disconnected) PCM connector E (80P) - Refer to: PCM Connector for Inputs and Outputs (1.5L Engine) or PCM Connector for Inputs and Outputs(2.0L Engine) (2024 2025) female terminals
IG Mode
Normal Conditions
VCENT shorted to ground inspection
OFF
There is more than 1 MOhm
Results
- If abnormal, there is a problem in the circuit.