Power Supply (VB1) Circuit Inspection
Test Procedure
- Preparation
- TCM connector A (23P) : disconnected
- Procedure
- Perform the inspection according to the following table.
(Disconnected)
TCM connector A (23P) female terminalsIG Mode Normal Conditions VB1 circuit inspection OFF 12 V battery voltage [ circuit type 1 ]
- Perform the inspection according to the following table.
Results
- If abnormal, there is a problem in the circuit.NOTE:
If the result is not in the normal condition while in the power supply inspection, refer to the Power Supply Inspection , then specify the failure part.
- If normal, there is a problem with the TCM.