Malfunction Threshold
- The misalignment of zero point pressure inside the fuel tank is 0.7 kPa (0.2 inHg, 5 mmHg) or more.
- The output from the FTP sensor flickering is 3.1 seconds or more.
- The change rate of the pressure rise slope inside the fuel tank is 2.8 or more.
- The change rate of the pressure descending slope inside the fuel tank is 0.8 or more.
- The barometric pressure is stable for at least 29 minutes, 58 seconds.